We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Consensus-based technical recommendations for clinical translation of renal ASL MRI

Checking your access to this record.

Abstract & Overview

Abstract Objectives This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. Methods An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. Results Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. Discussion This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.

Cite this record

Fábio Nery, Charlotte E. Buchanan, Anita A. Harteveld, Aghogho Odudu, Octavia Bane, Eleanor F. Cox, et al. (2019). Consensus-based technical recommendations for clinical translation of renal ASL MRI. Magnetic Resonance Materials in Physics Biology and Medicine, 33(1), 141–161. https://doi.org/10.1007/s10334-019-00800-z

Copy in another style

Nery, F., Buchanan, C. E., Harteveld, A. A., Odudu, A., Bane, O., Cox, E. F., Derlin, K., Gach, H. M., Golay, X., & Gutberlet, M. (2019). Consensus-based technical recommendations for clinical translation of renal ASL MRI. Magnetic Resonance Materials in Physics Biology and Medicine, 33(1), 141–161. https://doi.org/10.1007/s10334-019-00800-z
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.