We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Sonographic Assessment of The Impact of Heart Lung Interactions on Success of Weaning from Mechanical Ventilation
PeriodicalsMedical Sciences

Sonographic Assessment of The Impact of Heart Lung Interactions on Success of Weaning from Mechanical Ventilation

Checking your access to this record.

Abstract & Overview

Objective: Evaluation of lung ultrasound and echocardiography in weaning induced lung congestion and its impact on the weaning outcome.Background:Ultrasound can detect lung edema during weaning due to increased cardiac filling pressuresPatients and Methods:prospective study that included 40 critically ill ventilated patients ready for weaning as per readiness criteria. Eligible ptns performed echocardiography,lung ultrasonography& serum NT-proBNP.Results: Forty-patients were included. Weaning failure was 57.5% (n =23 patients); of them,14 patients (35%) had the failure during the SBT. A statistically significant difference was found between each of lung ultrasound score (LUS) during PPV &SBT and weaning results (P = 0.006 and 0.026) respectively. A cut off value of 5.5 for LUS during PPV predicted weaning failure at sensitivity of 73.9% and specificity of 64.7 % (AUC=0.752). A cut off value of 5.5 for LUS during SBT predicted failure of weaning with a sensitivity of 73.9% and specificity of 64.7% (AUC=0.698).No significant difference was found for NT-proBNP measurements between failed&successful weaning groups. Echocardiographic parameters, E /e\ during PPV and SBT were higher in failed weaning group than successful weaning group (P = 0.005 and 0.002) respectively. A cut off value of 7.43 for E/e\ during PPV predicted weaning failure at sensitivity of 69.6% and a specificity of 64.7 % (AUC=0.762).Cut off value of 8 of E/e\ during SBT predicted weaning failure at a sensitivity of 82.6% and a specificity of 64.7% (AUC=0.793)Conclusions: Prediction of weaning failure using lung & cardiac U/S before start of weaning is safe.

Cite this record

Sherif Sabry, Hamdy Mohamed Saber, Khalaf Ibrahim Eldehily, Mostafa Omar (2022). Sonographic Assessment of The Impact of Heart Lung Interactions on Success of Weaning from Mechanical Ventilation. The Egyptian Journal of Intensive care and Emergency Medicine ./The Egyptian Journal of Intensive care and Emergency Medicine, 2(2), 1–20. https://doi.org/10.21608/jicem.2022.170632.1010

Copy in another style

Sabry, S., Saber, H. M., Eldehily, K. I., & Omar, M. (2022). Sonographic Assessment of The Impact of Heart Lung Interactions on Success of Weaning from Mechanical Ventilation. The Egyptian Journal of Intensive care and Emergency Medicine ./The Egyptian Journal of Intensive care and Emergency Medicine, 2(2), 1–20. https://doi.org/10.21608/jicem.2022.170632.1010
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.