Abstract & Overview
A glucose biosensor has been fabricated by using ZnS nanoparticle-substituted graphene nanosheets.Thermally exfoliated graphene nanosheets act as a suitable support for the deposition of ZnS nanoparticles.In this work, graphene was functionalized with ZnS nanoparticles by a simple chemical reduction method.The synthesized G/ZnS nanoparticles have been characterized using X-ray diffractometry (XRD), Transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), FT-IR techniques.Aditionally, the Glucose biosensor has been constructed by drop-casting G/ZnS over a conductive carbon support followed by the deposition of Glucose oxidase (GOx) over a G/ZnS electrode.The performance of the biosensor was investigated by an electrochemical method.The resultant bioelectrode retains its biocatalytic activity and offers fast, highly-sensitive glucose quantification and a shelf-life of about 10 weeks under refrigerated conditions.